Skip Navigation

European Journal of Heart Failure 2005 7(6):974-983; doi:10.1016/j.ejheart.2004.11.002
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Skrabal, F.
Right arrow Articles by Holler, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Skrabal, F.
Right arrow Articles by Holler, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 2005 European Society of Cardiology

Multi-site-frequency electromechanocardiography for the prediction of ejection fraction and stroke volume in heart failure

Falko Skrabal*, Harald Mayer, Elke Hopfgartner, Gerfried Gratze, Gerhard Haitchi and Albert Holler

Department of Internal Medicine, Krankenhaus Barmherzige Brüder, Teaching Hospital, Graz Medical University Marschallgasse 12, A8020 Graz, Austria

* Corresponding author. E-mail address: falko.skrabal{at}meduni-graz.at


   Abstract

Background: Methods for stroke volume (SV) and ejection fraction (EF) measurements require the presence of qualified physicians and are not suited for continuous monitoring.

Aim: To develop an automated non-invasive method for the measurement and continuous monitoring of SV and EF.

Methods: We have designed a method for the measurement of EF and SV using multiple-site-impedance (z0) measurements, applying multiple frequencies of 5, 40 and 200 kHz whereby various segments of the human body, including volume changes within these segments, could be defined electrically. The obtained variables were used to train neuronal nets and related by multiple regression analyses to cardiac output (CO) as measured by a partial rebreathing Fick method (COr-fick) or EF as measured by echocardiography (EFecho), respectively. A total of 129 subjects (48 with normal heart function and 81 with CHF, NYHA I–IV) were investigated.

Results: The multiply derived values of z0 and of change of impedance (dz/dt) were shown, by multiple regression analysis, to be significantly related to COr-fick and to EFecho, (total r=0.77, n=35, p<0.001, and r=0.81, n=47, p<0.001, respectively.). By training a neuronal net with the electrical data of 67 (out of 94) subjects, EFecho could be predicted in the remaining 27 subjects which were unknown to the neuronal net with a combined r=0.71 (p<0.001,n=27). In contrast, conventional impedance cardiography (ICG) was unable to predict either COr-fick or EFecho.

Conclusion: The new method, which we call multi-site-frequency electromechanocardiography (msf-ELMC) appears promising for the automated electrical measurement of the mechanical heart action in patients with normal and reduced cardiac function.

Key Words: Cardiac output • Stroke volume • Ejection fraction • Chronic heart failure • Myocardial contraction • Electromechanocardiography • ELMC • Impedance cardiography

Received April 30, 2004; Revised September 24, 2004; Accepted November 11, 2004


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.