Skip Navigation

European Journal of Heart Failure 2003 5(4):523-526; doi:10.1016/S1388-9842(03)00004-7
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Kolb, C.
Right arrow Articles by Schmitt, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kolb, C.
Right arrow Articles by Schmitt, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 2003 European Society of Cardiology

Strategies to avoid inappropriate therapies due to ventricular double detection in biventricular pacing implantable cardioverter/defibrillators

Christof Kolb*, Bernhard Zrenner, Jürgen Schreieck and Claus Schmitt

Deutsches Herzzentrum München und 1. Med. Klinik, Klinikum rechts der Isar der Technischen Universität München, Elektrophysiologie Lazarettstr. 36, 80636 Munchen, Germany

* Corresponding author. Tel.: +49-89-12182020; fax: +49-89-12184593 kolb{at}dhm.mhn.de


   Abstract

Implantation of biventricular pacing implantable cardioverter/defibrillators (ICD) is a new therapeutic approach for the treatment of chronic heart failure and the prevention of sudden cardiac death. Due to a common left and right ventricular sensing channel in first generation biventricular pacing ICD, ventricular double sensing and subsequent delivery of inappropriate therapies occurs in some patients. A case of inappropriate anti-tachycardia pacing due to ventricular double detection is described. After programming short postventricular atrial refractory period, abandoning postventricular atrial refractory period extension in case of ventricular premature beats, increased upper rate limits and after careful selection of tachycardia detection criteria and anti-tachycardia programming no further inappropriate therapy occurred.

Key Words: Cardiac resynchronisation • Implantable cardioverter/defibrillator • Inappropriate therapies • Double detection

Received June 19, 2002; Revised October 3, 2002;
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.