Skip Navigation

European Journal of Heart Failure 2003 5(3):253-259; doi:10.1016/S1388-9842(02)00250-7
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Ohlsson, A.
Right arrow Articles by Bennett, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ohlsson, A.
Right arrow Articles by Bennett, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 2002 European Society of Cardiology

Central hemodynamic responses during serial exercise tests in heart failure patients using implantable hemodynamic monitors

Å. Ohlssona, D. Steinhausb, B. Kjellströmc, L. Rydend,* and T. Bennettc

a Southern Hospital Stockholm, Sweden
b St. Luke's Hospital Kansas, MO, USA
c Medtronic Inc Minneapolis, MN, USA
d Department of Cardiology, Karolinska Hospital S-171 76 Stockholm, Sweden

* Corresponding author. Tel.: +46-8-51773161; fax: +46-8-311044. E-mail address: lars.ryden{at}ks.se


   Abstract

Introduction: Exercise testing is commonly used in patients with congestive heart failure for diagnostic and prognostic purposes. Such testing may be even more valuable if invasive hemodynamics are acquired. However, this will make the test more complex and expensive and only provides information from isolated moments. We studied serial exercise tests in heart failure patients with implanted hemodynamic monitors allowing recording of central hemodynamics.

Methods: Twenty-one NYHA Class II–III heart failure patients underwent maximal exercise tests and submaximal bike or 6-min hall walk tests to quantify their hemodynamic responses and to study the feasibility of conducting exercise tests in patients with such devices.

Results: Patients were followed for 2–3 years with serial exercise tests. During maximal tests (n=70), heart rate increased by 52±19 bpm while SvO2 decreased by 35±10% saturation units. RV systolic and diastolic pressure increased 29±11 and 11±6 mmHg, respectively, while pulmonary artery diastolic pressure increased 21±8 mmHg. Submaximal bike (n=196) and hall walk tests (n=172) resulted in SvO2 changes of 80 and 91% of the maximal tests, while RV pressures ranged from 72 to 79% of maximal responses.

Conclusions: An added potential value of implantable hemodynamic monitors in heart failure patients may be to quantitatively determine the true hemodynamic profile during standard non-invasive clinical exercise tests and to compare that to hemodynamic effects of regular exercise during daily living. It would be of interest to study whether such information could improve the ability to predict changes in a patient's clinical condition and to improve tailoring patient management.

Key Words: Exercise testing • Hemodynamic monitoring • Heart failure

Received May 2, 2002; Revised July 15, 2002; Accepted September 25, 2002


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur J Heart FailHome page
F. Braunschweig, C. Linde, P. B. Adamson, A. Magalski, E. Erdmann, B. Kjellstrom, and T. Bennett
Continuous central haemodynamic measurements during the six-minute walk test and daily life in patients with chronic heart failure
Eur J Heart Fail, June 1, 2009; 11(6): 594 - 601.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.